Transfer
Changeover & ATS
MCB Changeover manually switching to an alternate source power supply — plus ACCL automatic changeover with current limiter.
MCB Changeover manually switching to an alternate source power supply. MCB Changeover Switch usage in industries & domestic area especially for use in low voltage distribution circuits. MCB switchover switches are used to shift from one source to another source and vice-versa.
The changeover switch comes in 2P and 4P versions. It has three positions (I-O-II) with centre-off. They are switch disconnectors with the independent manual operation, capable of making, carrying and breaking currents under normal circuit conditions.

Features
MCB Changeover Switch.
- 01Compact ConstructionCompact size and easy mounting.
- 02Silver Contact TipsFor better electrical conductivity.
- 03Centre position offFront operation with three stable positions I-O-II, Off at middle position.
- 04MountingEasy snap on DIN Rail mounting. Vertical and can be mounted with other products like MCB, RCCB & Isolators in distribution board.
- 05ContactsDouble Break Contacts.

ACCL
Automatic Changeover with Current Limiter (ACCL)
A changeover device, which on failure of Mains power supply, automatically transfers the load from Mains power supply to Generator supply. It also functions as a Load Limiter with monitoring of current drawn from Generator, thereby reducing stress on the Generator for Seamless Changeover between Power Sources.
ACCL Features
Automatic transfer with load management.
- 01Potential free contact for connecting power load (Single Phase/Relay Version)Compact size saving panel space
- 02Dual Interlock between Mains & Gen supply (Electrical & Mechanical)Manual reset provision
- 03Automatic Generator Start/StopOverload monitoring of Generator supply
- 04Indication of status through coloured LEDBreak before make changeover system
- 05Reduced wiring cost as single phase ACCL has separate control for power and lighting offIntelligent re-connection once trip has occurred due to either over voltage or overload.
- 06Under and Over voltage protection when load is running on DGMicrocontroller based automatic source changeover with neutral isolation.
- 07Staggered terminal design for better isolation between phase and neutralEco friendly thermoplastic and fire retardant body cover.
Certified excellence
Quality is not a department. It is the whole factory.
ISO 9001:2015 and CE-certified operations. BIS/ISI licensed manufacturing audited annually against IEC/IS standards — from raw material to finished pole.
Explore more
Related product families.
Looking for perfect electrical switchgear solutions
For the harshest environments and specialist applications. Get in Touch with Us Today. Connect with our support executive to learn more.